/Catalyst
Catalyst2018-04-23T18:34:56-05:00

Catalyst HD

La respuesta precisa para la terapia de radiación estereotáctica

Caracteristicas:

The capability of linear accelerators to deliver higher doses for SRT is increasing and it is expected that this technique will be applied more widely in clinical settings. To deliver even higher doses, new technology must be provided that is compatible with stereotactic delivery, namely high-precision patient positioning and intra-fraction motion management.

Catalyst HD offers a complete Surface Image Guided Radiation Therapy (SIGRT) solution on SRT for online patient tracking before and during treatment delivery, thus ensuring the best possible treatment outcome without non-prescribed doses. The Catalyst HD can also be used for VMAT, IMRT and 3D CRT delivery.

Provide real time SIGRT through the treatment workflow, from Setup and Positioning, Intra-Fraction Motion Monitoring to Respiratory Gating Treatment with submillimeter accuracy for non-coplanar treatment
Large patient surface coverage (1300x800x700mm) with optimal 360-degree coverage, fully support non coplanar delivery.
Patented color map projected on patient body during setup.
During treatment, the patient is constantly under surveillances by Catalyst HD.
Dedicated Stereotactic Module is available for SRS/SBRT delivery,
Dose-free motion management
Auto patient data retrieve
No markers on or around the patient
Audio-visual coaching through in-room speakers and video solution, assisting the patient to follow the optimal breathing pattern.
Multi-vendor interfaces have been developed to ensure the seamless clinical workflow, i.e. Varian TrueBeam, C-series; Elekta VersaHD, Infinity, Synergy; IBA UBTI.
All patient data is available from a central database in the network environment.
Potential to improve quality and speed of the positioning process, for example, extremity sarcoma
Highly integrated QA/QC procedure – Daily QC within 5 minutes
Non-rigid algorithm avoids extra time for ROI design.
Positioning accuracy: Within 0.5 mm for rigid body
Long term stability: 0.3 mm
Registration method: Real-time, non-rigid with deformable models for computing 6 DOF isocentric shifts

Catalyst

Evolución en el tratamiento 4D

Caracteristicas:

During treatment, patient breathing, as well as movements of the tumor or normal tissue can impact the clinical result and by missing targets or causing extra dose distribution to normal tissue.

The Catalyst system is a revolutionary solution for Surface Image Guided Radiation Therapy (SIGRT), coupled with application software optimized for work-flow integration.

Catalyst offers a complete solution on 3D CRT, IMRT for online patient tracking before and during treatment delivery, thus ensuring the best possible therapeutic and palliative treatment outcome without non-prescribed doses. c4D software is integrated with major radiation therapy equipment suppliers to streamline workflow, including beam and couch control.

Real time SIGRT solution for the whole 4D treatment workflow, from Setup and Positioning to Intra-Fraction Motion Monitoring to Respiratory Gating Treatment.
Patented color map projected on patient body during setup for immediate posture correction by patient.
Respiratory gating treatment support.
Breath-hold, deep inspiration and coached/free breathing modes are all supported.
Optional audio-visual coaching helps the patient follow optimal breathing patterns. Patient baseline is calculated as an absolute parameter that can be used during treatment delivery.
Dose-free motion management
Auto patient data retrieve
No markers on or around the patient
Audio-visual coaching through in-room speakers and video solution, assisting the patient to follow the optimal breathing pattern.
Multi-vendor interfaces have been developed to ensure the seamless clinical workflow, i.e. Varian TrueBeam, C-series; Elekta VersaHD, Infinity, Synergy; IBA UBTI.
All patient data is available from a central database in the network environment.
Potential to improve quality and speed of the positioning process, for example, extremity sarcoma
Highly integrated QA/QC procedure – Daily QC within 5 minutes
Non-rigid algorithm avoids extra time for ROI design.
Positioning accuracy: Within 0.5 mm for rigid body
Long term stability: 0.3 mm
Registration method: Real-time, non-rigid with deformable models for computing 6 DOF isocentric shifts

Sentinel ™

El nuevo punto de referencia en 4D CT

Caracteristicas:

With a normal CT scan, motion may cause inaccurate target definition, in that moving targets could be in distorted shapes at the wrong location. It could also cause extra dose distribution to healthy tissue, due to dosing larger fields to cover a moving tumor.

To improve the visualization of moving tumors, 4D CT is applied to determine the motion and help to design an accurate plan for employing precise standard or gated therapy.

C-RAD Sentinel 4D CT is an easy-to-use, laser-based optical surface scanning system with functionality for 4D CT reconstruction and gated imaging in a CT room. It also provides reference images for patient positioning and intra-fraction motion detection in a radiation therapy treatment room.

Real time SIGRT solution for the whole 4D treatment workflow, from Setup and Positioning to Intra-Fraction Motion Monitoring to Respiratory Gating Treatment.
Patented color map projected on patient body during setup for immediate posture correction by patient.
Respiratory gating treatment support.
Breath-hold, deep inspiration and coached/free breathing modes are all supported.
Optional audio-visual coaching helps the patient follow optimal breathing patterns. Patient baseline is calculated as an absolute parameter that can be used during treatment delivery.
Dose-free motion management
Auto patient data retrieve
No markers on or around the patient
Audio-visual coaching through in-room speakers and video solution, assisting the patient to follow the optimal breathing pattern.
Multi-vendor interfaces have been developed to ensure the seamless clinical workflow, i.e. Varian TrueBeam, C-series; Elekta VersaHD, Infinity, Synergy; IBA UBTI.
All patient data is available from a central database in the network environment.
Potential to improve quality and speed of the positioning process, for example, extremity sarcoma
Highly integrated QA/QC procedure – Daily QC within 5 minutes
Non-rigid algorithm avoids extra time for ROI design.
Positioning accuracy: Within 0.5 mm for rigid body
Long term stability: 0.3 mm
Registration method: Real-time, non-rigid with deformable models for computing 6 DOF isocentric shifts

Contacto

TELEFONOS:

+571 474 83 64

DIRECCIÓN

CALLE 89 A Nº 20 – 25

CORREO

CONTACTO@ARTCORPORATIONSA.COM